How to Clear a Fault

When a fault occurs, the cause must be corrected before the fault can be cleared.
After corrective action has been taken, any of the following actions will clear the
fault.

• Press the CopyCat Keypad Stop button

• Set P54 - [Clear Fault] to 1.

• Disconnect power to the drive, wait three minutes, reapply power.

• Cycle the input signal at TB3-8 to the drive.

Please consult the 160 SSC™ Variable Speed Drive (Series C) User Manual,
Publication 0160-5.15, for a complete listing of fault descriptions and possible
problems and corrective actions.

ATTENTION: Only personnel familiar with the drive and associated
machinery should plan or implement the installation, start-up, and
subsequent maintenance of the system. Failure to comply may result
in personal injury and/or equipment damage.

ATTENTION:

Ensure that you disconnect line power and wait three

minutes before installing or removing the Ready/Fault Indicating
Panel or Program Keypad Module. Failure to do so could result in
personal injury or death.