Monitoring drive status, Chapter – Rockwell Automation 160 160SSC CopyCat Keypad User Manual

Page 25

Advertising
background image

Chapter

4

Monitoring Drive Status

The CopyCat Keypad Display mode is used to monitor Display Group parameter
values. When serial communication with the drive has been established after power
up, the CopyCat Keypad automatically enters Display mode.

Display Group Parameters

In Display mode, the display shows the name, number, and the value of the currently
selected Display Group parameter. For example:

Not all Display Group parameters apply to both the Analog Signal Follower and
Preset Speed model drives. Refer to 160 SSC™ Variable Speed Drive (Series C)
User Manual for more information on Display Group parameters.

Select a Display Group Parameter

There are two methods for selecting a Display Group parameter. You can either
scroll through the parameter list, or enter the parameter number with the numeric
keypad.

Method 1 – Scroll Parameter List

1. Press the Escape key until the Program LED and Load LED are both off.

2. Press the Up or Down arrow key to scroll to the next or previous parameter.

Press and hold the Up or Down arrow key to increase scrolling speed.

The name, number, and value of the newly selected parameter is displayed.

Method 2 – Enter Parameter Number

1. Press the Escape key until the Program LED and Load LED are both off.

2. Enter the two-digit parameter number that you want to display using the

numeric keys.

The display shows the parameter number you entered. For example >06.

To correct an entry, press the Delete key.

Important:

To select and view Display Group parameters, the CopyCat
Keypad must be in Display mode.