SMC Dialog Plus Smart Motor Controller

3-23

Pump Control Option

The SMC Dialog Plus controller’s unique interactive Pump Control is
designed to reduce fluid surges in pumping systems. It provides
closed loop acceleration and deceleration control of centrifugal pump
motors without the need for feedback devices.

Figure 3.19 Pump Control Option

Pump Start

Run

Pump Stop

Motor

Speed

100

Time (seconds)

!

ATTENTION: Pump Stop is not intended to be used
as an emergency stop. Refer to the applicable standards
for emergency stop requirements.