Smb smart motor braking option – Rockwell Automation 150 MNL/SMC DIALOG+/APP-PROD GUIDE User Manual

Page 69

Advertising
background image

3-32

SMC Dialog Plus Smart Motor Controller

Control Options (cont.)

SMB

Smart Motor Braking Option

The SMB Smart Motor Braking option provides motor braking for
applications which require the motor to stop quickly. It is a
microprocessor based braking system which applies braking current
to a standard squirrel cage induction motor. The strength of the
braking current is adjustable from 150 to 400% of full load current.

Figure 3.25 SMB Smart Motor Braking Option

Start

Motor

Speed

100

Run

Automatic Zero Speed

Shut-off

Brake

Smart Motor Braking

Coast-to-rest

Time (seconds)

!

ATTENTION: Braking may cause motor heating and
equipment vibration depending on braking current,
frequency of braking, and duration of braking cycle.
Select the lowest brake current setting that will brake
satisfactorily.

!

ATTENTION: SMB Smart Motor Braking is not
intended to be used as an emergency stop. Refer to the
applicable standards for emergency stop requirements.