Application Examples 7-17

File 3 (Continued)

The following table shows configuration and control words for the
ladder program. The table is showing integer file N7 in the Decimal
Radix. Words N7:0 through N7:15 contain the configuration words for
analog channels 0 to 15 to send analog data to the controller. These
configurations and control words must be viewed in the Binary Radix
because they are bit-mapped. Please refer to Chapter 5, Channel
Configuration, Data and Status for an explanation of each bit in these
words. For this example, each channel has been configured for
0 to 10vdc, 1746-NI14 data format and a filter frequency of 60 Hz.

Data File N7

0032

B3:3

0

L

B3:3

1

0033

B3:2

8

B3:2

9

B3:2

10

B3:2

11

B3:2

12

B3:2

13

B3:2

14

B3:2

15

L

B3:3

0

U

B3:3

1

CLR

Clear
Dest

B3:2

0000000000000000<

CLR

0034

END

CH 15 Configuration

Complete

CH 8 Configuration

Complete

CH 9 Configuration

Complete

CH 10 Configuration

Complete

CH 11 Configuration

Complete

CH 12 Configuration

Complete

CH 13 Configuration

Complete

CH 14 Configuration

Complete

Offset

0

1

2

3

4

5

6

7

8

9

N7:0

-16142

-16142

-16142

-16142

-16142

-16142

-16142

-16142

-16141

-16141

N7:10

-16141

-16141

-16141

-16141

-16141

-16141

0

0

0

0

N7:20

-32768

-32768

-32768

-32768

-32768

-32768

-32768

-32768

-32767

-32767

N7:30

-32767

-32767

-32767

-32767

-32767

-32767

0

0

0

0

Advertising