Chapter 2 Safe Torque-off Connector Data

In this example, the Kinetix 6000 axis module is shown with a first-drive wiring
header (catalog number 2090-XNSM-W). Kinetix 6000 and Kinetix 7000 first-
drive modules use this header in multiple safe torque-off drive configurations for
wiring to a safety control circuit and extending the safe torque-off circuitry to
another drive.

Figure 8 - First-drive Wiring Header (2090-XNSM-W)

Figure 9 - First-drive Wiring Header Pin Assignment

Kinetix 6000 or Kinetix 7000 Drive

(Kinetix 6000 axis module is shown)

Safe Torque-off terminals for

input wiring (STO-1…STO-7).

Cable connector to second

drive in safety circuit.

IMPORTANT

Do not use the first-drive (2090-XNSM-W) wiring header in single-drive
applications.

SO-1 2 3 4 5 6 7