Kinetix 6000 (series c) servo drives – Rockwell Automation 2099-BMxx-S Kinetix Safe Torque-off Feature Safety Reference Manual User Manual

Page 30

Advertising
background image

30

Rockwell Automation Publication GMC-RM002F-EN-P - June 2013

Appendix A Specifications

Table 9 - Relay Contact Specifications for the FDBK Signals

Kinetix 6000 (series C) Servo Drives

Table 10 - Safe Torque-off Signal Specifications

For additional information regarding Allen-Bradley safety products, including
safety relays, light curtain, and gate interlock applications, refer to the Safety
Products Catalog, website

http://www.ab.com/catalogs

.

Attribute

Value

Contact Resistance (1 A, 24V DC)

100 m

Contact Resistance (10 mA, 5V DC)

20

Contact Load (min)

10 mA, 5V DC

Rated Current

5 A

Rated Voltage

240V ac

Breaking Capacity, ac (max) for resistive loads

1250VA

Attribute

Value

Input current

< 10 mA

Input ON voltage range

18…26.4V DC

Input OFF voltage, max

5V DC

Input OFF current

2 mA @ V in < 5V DC

Pulse rejection width

700

µs

External power supply

SELV/PELV

Input type

Optically isolated and reverse voltage protected

Advertising