Wire the safe torque-off circuit, Chapter 3, Wiring your kinetix safe torque-off drive – Rockwell Automation 2099-BMxx-S Kinetix Safe Torque-off Feature Safety Reference Manual User Manual

Page 21: Chapter

Advertising
background image

Rockwell Automation Publication GMC-RM002F-EN-P - June 2013

21

Chapter

3

Wiring Your Kinetix Safe Torque-off Drive

This chapter provides guidelines for wiring your Kinetix 6000 and Kinetix 7000
safe torque-off drive connections.

Wire the Safe Torque-off
Circuit

This section provides guidelines for wiring your Kinetix 6000 and Kinetix 7000
safe torque-off drive connections.

Topic

Page

Wire the Safe Torque-off Circuit

21

Safe Torque-off Wiring Requirements

22

Safe Torque-off Feature

23

IMPORTANT

The National Electrical Code and local electrical codes take precedence over the
values and methods provided.

IMPORTANT

To improve system performance, run wires and cables in the wireways as
established in

Establishing Noise Zones

beginning on

page 33

.

IMPORTANT

Pins STO-8 (internal 24V+ supply) and STO-9 (24V_COM) are used only by the
motion-allowed jumper to defeat the safe torque-off function. When the safe
torque-off function is in operation, the 24V supply must come from an external
source.

Advertising