Publication ICM-UM001C-EN-E - March 2013

31

Configure the Adapter Chapter 3

The New Module dialog box opens.

4. From the General tab, enter the following information.

5. Click OK to close the dialog box.

On this tab

In this field

Enter

General

Name

Enter a unique name for the module.

Node Address

Enter the node address of the module. This number and the dip

switches on the module must match.

DIP switches 5 through 10 set the module’s node address using

binary addressing.

We recommend that you set the node address to the position of

the module. For example, the module next to the adapter is node

address 1. If there are two module between this module and the

adapter, the node address is 3.

Refer to the XM Dynamic Measurement Module User Manual,

publication

ICM-UM002

, for more information about the dip

switches.