Technical features – Carlo Gavazzi PQT-90 User Manual

Page 32

Advertising
background image

PQT-90 Instruction manual

Technical features

67

61

PQT-90 Instruction manual

60

Technical features

59

Continuous: voltage/current: AV5: 300V

L-N

/ 500V

L-L

/ 6A

AV7: 480V

L-N

/ 830V

L-L

/ 6A

For 1s: voltage/current: AV5: 600V

L-N

/1040V

L-L

/120A

AV7: 960V

L-N

/1660V

L-L

/120A

Output specifications

Analogue outputs (on request)
Number of outputs: up to 4
Accuracy: ±0.2% f.s. (@ 25°C ±5°C, R.H.

60%)

Range: 0 to 20 mADC, 0 to ±20 mADC 0 to ±10 mADC,
0 to ±5 mADC 0 to 10 VDC, 0 to ±10 VDC 0 to ±5 VDC,
0 to ±1 VDC
Scaling factor: programmable within the whole range of
retransmission; it allows the retransmission management of
all values from: 0 to 20 mADC, 0 to ±20 mADC, 0 to
±10mADC, 0 to ±5 mADC, 0 to 10 VDC, 0 to ±10 VDC, 0 to
±5 VDC, 0 to ±1 VDC. Variables to be retransmitted: all.
Response time:

200 ms typical (filter excluded, FFT exclud-

ed).
Ripple:

1% according to IEC 60688-1 and EN 60688-1.

Temperature drift:

200 ppm/°C.

Load: 20 mADC

600

, ±20 mADC

550

, ±10 mADC

1100

, ±5 mADC

2200

, 10 VDC

10 k

, ±10 VDC

10k

,

±5 VDC

10k

, ±1 VDC

10k

.

Insulation by means of optocouplers: 4000 V

RMS

output to

measuring input 4000 V

RMS

output to supply input.

RS422/RS485 (on request): bidirectional (static and dynamic
variables). Connections: 2 or 4 wires, max. distance: 1200m,
termination directly on the module.
Addresses: from 1 to 255, software programmable.
Protocol: MODBUS RTU/JBUS. Data format: (bidirectional).
Dynamic (reading only): all variables.

±0.5% (RDG + FS) (PF 0.5 L/C, 0.1 to 1.2 In, range AV5) or
±1% RDG (PF 0.5 L/C, 0.1 to 1.2 In, range AV5)
Apparent power (@ 25°C ± 5°C, R.H.

60%):

±0.5% (RDG + FS) (0.1 to 1.2 In, range AV5) or ±1% RDG

(0.1 to 1.2 In, range AV5).
Energies (@ 25°C ± 5°C, R.H.

60%): Active: class 1 accord-

ing to EN61036. Reactive: class 2 according to EN61268, Ib:
5A, Imax: 6A 0.1Ib: 500mA Start-up current: 20mA Un: 240V
(AV5), 400V (AV7).
Harmonic distortion: 1% FS (FS: 100%) (@ 25°C ± 5°C, R.H.

60%) phase: ±2°; Imin: 0.1Arms; Imax: 15Ap; Umin: 50V

RMS

;

Umax: 500Vp. Sampling frequency 6400 samples/s @ 50Hz
Additional errors:
Humidity

0.3% RDG, 60% to 90% R.H.

Input frequency:

0.4% RDG, 62 to 400 Hz.

Magnetic field:

0.5% RDG @ 400 A/m

NOTE: all accuracies are referred to measurements carried out
with the analogue input module.
Temperature drift:

200ppm/°C.

Sampling rate: 6400 samples/s @ 50Hz.

Measurements: current, voltage, power factor, energy, power
factor, frequency, harmonic distortion. TRMS measurement of a
distorted wave. Coupling type: direct. Crest factor:

3, max.

15Ap/500Vp AV5 (L-N), 15Ap/800Vp AV7 (L-N)

Ranges (impedances)
AV5:
58/100 V (> 500 k

) - 1 AAC (

0.3 VA)

58/100 V (> 500 k

) - 5 AAC (

0.3 VA)

240 V/415 V (> 500 k

) -1 AAC (

0.3 VA)

240 V/415 V (> 500 k

) -5 AAC (

0.3 VA)

AV7: 100/170 V (> 500 k

) -1 AAC (

0.3 VA)

100/170 V (> 500 k

) - 5 AAC (

0.3 VA)

400/690 V (> 500 k

) - 1 AAC (

0.3 VA)

400/690 V (> 500 k

) - 5 AAC (

0.3 VA)

Frequency: 40 to 440 Hz
Overload protection: