Operations on the cascade slave ls9 – Yamaha LS9 User Manual

Page 210

Advertising
background image

210

Using cascade connections

LS9-16/32 Owner’s Manual

1

In the DISPLAY ACCESS section, press the
[SETUP] key repeatedly to access the SYS-
TEM SETUP screen.

1

CASCADE OUT button

2

In the MIXER SETUP field located at the
lower part of the SYSTEM SETUP screen,
move the cursor to the CASCADE OUT but-
ton and press the [ENTER] key.

The CASCADE OUT PATCH popup window will
appear. This window contains the following items.

1

Port select popup buttons

These buttons access an OUTPUT PORT SELECT
popup window where you can select the output port
for each bus.

B

CASCADE LINK PORT field

When using the Cascade Link function, this specifies
the port by which control signals will be transmitted
and received between the two LS9 consoles.

C

CASCADE COMM LINK field

Here you can select the parameters and events that will
be linked by the Cascade Link function.

3

Move the cursor to the port select popup
button for the bus whose port you want to
assign, and press the [ENTER] key.

The OUTPUT PORT SELECT popup window will
appear.

[ OUTPUT PORT SELECT popup window for
the LS9-32 ]

[ OUTPUT PORT SELECT popup window for
the LS9-16 ]

This popup window contains the following items.

1

Port select buttons

These buttons select the output port for the selected
bus.

B

Slot select tabs (LS9-32 only)

These tabs select slots 1/2.

4

Use the port select buttons {slot select tabs
and port select buttons} to select an output
port, move the cursor to the CLOSE button
and press the [ENTER] key.

The port will be assigned to the bus you selected in
step 3.

5

Repeat steps 3 and 4 to assign output ports
to other buses.

Operations on the cascade slave
LS9

LS9-32

1

1

2

3

2

1

1

• You can’t assign two or more buses to the same output port. If

you select a bus to which a signal route has already been
assigned, the previous assignment will be cancelled.

NOTE