Baumer G0-GB-GXP5W/S/H-GXU5W/S User Manual

Page 20

Advertising
background image

Manual_G0-GB-GXP5-GXU5_406_EN.docx

20/48

Baumer IVO GmbH & Co. KG

20.11.12

Villingen-Schwenningen, Germany

01h All parameters

U32

rw

=“load“ (0x6C6F6164) to load

02h Communication parameters U32

rw

=“load“ (0x6C6F6164) to load

03h Application parameters

U32

rw

=“load“ (0x6C6F6164) to load

04h Manufacturer specific

parameters

U32

rw

=“load“ (0x6C6F6164) to load

1014h Emergency COB ID

U32

rw

80h +Node ID

1

COB ID of the emergency object

1016h Consumer heart beat time

ARR

00h Biggest subindex

ro

1h

01h Consumer heartbeat time

U32

rw

10000h

1

Bit0..15 Consumer Heartbeat time in ms
Bit16..23 Node-ID

1017h Producer heartbeat time

U16

rw

0h

1

Producer Heartbeat time in ms

1018h Identity object

U32

ro

00h Biggest subindex

U8

ro

4h

01h Vendor ID

U32

ro

ECh

1

Vendor no. issued by CiA

02h Product Code

U32

ro

18h
19h
14h
15h

ja

18h = GBP5 Multiturn
19h = GBU5 Singleturn
14h = GXP5 Multiturn
15h = GXU5 Singleturn

03h Revision number

U32

ro

Actual value

Current revision

04h Serial number

U32

ro

xyz

1

Unique consecutive serial number

1029h Error behavior

ARR

(V1.04+)

00h Biggest subindex

U8

ro

1h

01h Communication error

U8

rw

1h

1

0h = change to Pre-Operational Mode
1h = no Mode-change
2h = change to Stop Mode
3h = reset node

1800h Transmit PDO1 parameter

REC

00h Biggest subindex

U8

ro

5h

01h COB ID

U32

rw

180h+id

1

PDO ID = 180h + node ID

02h PDO type

U8

rw

FEh

1

FEh=User defined, cyclical

05h Event timer

U16

rw

203h

1

Cycle time in ms

1801h Transmit PDO2 parameter

REC

00h Biggest subindex

U8

ro

5h

01h COB ID

U32

rw

280h+id

1

PDO ID = 280h + Node ID

02h PDO type

U8

rw

2h

1

2h= synchronous operation

05h Event timer

U16

rw

100h

1

Cycle time in ms

1A00h Transmit PDO1 mapping

ARR

00h Biggest subindex

U8

ro

1h

01h Content of PDO1

U32

ro

60040020h

Read only, although from CiA as read write

1A01h Transmit PDO2 mapping

ARR

00h Biggest subindex

U8

ro

1h

01h Content of PDO2

U32

ro

60040020h

Read only, although from CiA as read write

2100h Baud rate

U8

rw

2h

1

After setting the baud rate, the EEPROM must
be saved and reinitialized

0=10 kBit/s
1=20 kBit/s
2=50 kBit/s
3=100 kBit/s
4=125 kBit/s
5=250 kBit/s
6=500 kBit/s
7=800 kBit/s
8=1000 kBit/s

2101h Node ID

U8

rw

1h

1

Node number 1 -127 possible
After setting the baud rate, the EEPROM must
be saved and reinitialized.

Advertising