Configuration – Baumer G0-GB-GXP5W/S/H-GXU5W/S User Manual

Page 42

Advertising
background image

Manual_G0-GB-GXP5-GXU5_406_EN.docx

42/48

Baumer IVO GmbH & Co. KG

20.11.12

Villingen-Schwenningen, Germany

Changing the baud rate
The baud rate can be changed in the object 2100h. An index is written into the object, not the effective baud
rate.

Baud rate

0

10 kBaud

1

20 kBaud

2

50 kBaud

3

100 kBaud

4

125 kBaud

5

250 kBaud

6

500 kBaud

7

800 kBaud

8

1000 kBaud


The baud rate now still has to be saved using object 1010-1. On next initialization, the encoder logs on to the
new baud rate. However, before this the baud rate of the master should be changed.

5.2. Configuration

Position setting
The value is transmitted:

COB ID

DLC Command

Object L

Object H Subindex Data 0

Data
1

Data
2

Data
3

600h+node ID

8

23h

03h

60h

0h

a

b

c

d


Conformation:

COB ID

DLC Command

Object L

Object H Subindex Data 0

Data
1

Data
2

Data
3

580h+node ID

8

60h

03h

60h

0h

0

0

0

0

Changing the sense of rotation and scaling
The sense of rotation can be set to CW (clockwise) or CCW (counterclockwise). In addition, the scaling can
be switched on or off in the same object (6000h). With the scaling switched on, the set resolutions are used.
However, if the scaling is switched off, the encoder works with the maximum resolution settings (6501h and
6502h).

Bit 0: 0 -> CW (clockwise)

Value: 0

1 -> CCW (counterclockwise)

Value: 1

Bit 2:

0 -> Scaling off

Value: 0

1 -> Scaling on

Value: 4


Counterclockwise rotation and scaling on:

COB ID

DLC Command

Object L

Object H Subindex Data 0 Data

1

Data
2

Data
3

600h+node ID

8

23h

00h

60h

0h

5h

x

x

x


Confirmation:

COB ID

DLC Command

Object L

Object H Subindex Data 0

Data
1

Data
2

Data
3

580h+node ID

8

60h

00h

60h

0h

0

0

0

0

Advertising