Baumer G0-GB-GXP5W/S/H-GXU5W/S User Manual

Page 22

Advertising
background image

Manual_G0-GB-GXP5-GXU5_406_EN.docx

22/48

Baumer IVO GmbH & Co. KG

20.11.12

Villingen-Schwenningen, Germany

6502h Overall measuring range in

increments

U32

ro

(1)00000000h

40000h

20000000h

2000h

Overall measuring range

in increments:

32Bit = GBP5 Multiturn
18Bit = GBU5 Singleturn
29Bit = GXP5 Multiturn
13Bit = GXU5 Singleturn

6503h Alarms

U16

ro

0h

The following alarms are evaluated:

Bit0=Position error

6504h Supported alarms

U16

ro

1h

The following alarms are supported:

Bit0=Position error

6505h Warnings

U16

ro

0h

The following warnings are evaluated:

Multiturn encoder:

Bit2 = CPU watchdog status
Bit4 = Battery charge

Singleturn encoder:

Bit2 = CPU watchdog status

6506h Supported warnings

U16

ro

14h


04h

The following warnings are supported:

Multiturn encoder:

Bit2 = CPU watchdog status
Bit4 = Battery charge

Singleturn encoder:

Bit2 = CPU watchdog status

6507h Profile & software version

U32

ro

01000201h

Byte 0..1:

Profile version =2.01 = 0201h

Byte 2..3:

Software version = 1.05 = 0105h

6508h Operating time

U32

ro

0h

Time in 1/10 hours since last reset

6509h Offset

U32

ro

0h

1

Offset calculated from preset  6003h

650Bh Serial number

U32

ro

xyz

1

Linked with serial number object 1018-4