Baumer G0-GB-GXP5W/S/H-GXU5W/S User Manual

Page 36

Advertising
background image

Manual_G0-GB-GXP5-GXU5_406_EN.docx

36/48

Baumer IVO GmbH & Co. KG

20.11.12

Villingen-Schwenningen, Germany

Object 6502

Max. overall measurement range in increments

Subindex

0

Data type

Unsigned 32

Access

Read only

Default

(1)00000000h = 4294967296 = 32Bit  GBP5 Multiturn
40000h = 262144 = 18Bit

 GBU5 Singleturn

20000000h = 536870912 = 29Bit

 GXP5 Multiturn

2000h = 8192 = 13Bit

 GXU5 Singleturn

EEPROM

No

Description

Maximum measurement range (the data type U32 in this object does
not correspond to the CiA profile)

Values

(1)00000000h = 4294967296 = 32Bit  GBP5 Multiturn
40000h = 262144 = 18Bit

 GBU5 Singleturn

20000000h = 536870912 = 29Bit

 GXP5 Multiturn

2000h = 8192 = 13Bit

 GXU5 Singleturn

Object 6503

Alarms

Subindex

0

Data type

Unsigned 16

Access

Read only

Default

0h

EEPROM

No

Description

Alarm messages as per object 6504h

Values

Bit 0 = 1  Position error active

Object 6504

Supported alarms

Subindex

0

Data type

Unsigned 16

Access

Read only

Default

1h

EEPROM

No

Description

Alarm messages supported by object 6503

Values

Bit 0 = Position error

Object 6505

Warnings

Subindex

0

Data type

Unsigned 16

Access

Read only

Default

0h

EEPROM

No

Description

Warnings as per object 6506h

Values

Multiturn:

Bit 2 = 1  CPU watchdog reset
Bit 4 = 1  Battery charge too low

Singleturn:

Bit 2 = 1  CPU Watchdog reset

Advertising