64

6.1.1.3

Record Setup

(1)

(2)

(3)

(4)

(1) Camera icon

Select the camera that user wants to set up. To select channel 01~ 04, mark All.

(2) Frame Rate Info Display

Display the total frame rate and the available frame rate info that deepens on the Max Frame
Rate
and Min Frame Rate setting of every camera.

(3) Record Mode

-

Resolution
Select D1/CIF/HD1 recording mode. Under D1 mode, the video recording is in full screen
resolution and takes turns from one channel to the next one when Auto Scan enables. Each
channel is recorded up to a maximum frame rate of 30/25fps(NTSC/PAL). User can switch to
view the video in full screen or QUAD screen. Whereas in CIF mode, video recording is at a
lower resolution, but each video is recorded in 30fps/25fps (NTSC/PAL). User can switch to
view the video in full screen or QUAD screen. In HD1 mode, each channel is recorded up to
a maximum frame rate of 30/25fps (NTSC/PAL). User can switch to view the video in full
screen or QUAD screen.

-

Max Frame Rate: Set the maximum number of frames to be recorded during motion and

motionless state. The higher the frame rate, it uses more hard disk space.

-

Min Frame Rate: Set the minimum number of frames to be recorded during motion and

motionless state. The higher the frame rate, it uses more hard disk space.

-

Video Quality: Adjust the video quality. The higher the value, the lower the compression

level and uses more hard disk space.

-

Sensor Trigger: Customize the initial state of the attached sensor.

Condition

Description

NOT INSTALLED

Indicates that there is no sensor connected

NORMAL OPEN

Indicates that the initial state of the sensor is normal open. Video
recording initiates when there is a changes in the sensor state

NORMAL CLOSE

Indicates that the initial state of the sensor is normal close. Video
recording initiates when there is a changes in the sensor state

-

Pre Record Time: set the time in second for the DVR system to pre-recording before the

alarm happen.

After Record Time: set the time in second for the DVR system to continue recording after
the alarm has ended.