EFCO 8800 Installation Instructions User Manual

Page 44

Advertising
background image

EFCO 2009

Page 44

Series 8700 / 8800 Unitized Curtain Wall Installation Instructions

30. Set the unit to the required elevation height and level it by turning the jack bolt at each mullion anchor clockwise to raise, or counterclockwise to lower the unit

in to the final position.

31. Match drill the slab anchors through the hook anchors on both sides of the unit, and install the pinning screws to lock the frame unit into the final position.

See Figures 95 and 96.

32. Repeat steps 5 through 31 until all units on the dynamic starter sill level have been installed.
33. When erecting a long run of units, check overall frame location dimensions at every fifth unit to avoid dimensional buildup and to ensure that units are

properly positioned with regard to established bench marks.

34. Proceed to “Section 10 - Setting Typical Intermediate Units”.

Section 9 - Setting Units at Dynamic Starter Sills

Figure 96

Figure 95

Hook Anchor

17D4 Slab
Anchor

Dead Load Anchor

Once the units are set and final
adjustments are made, turn the
washer so that the serrations
align and secure anchor bolts.

17D3 Serrated
Washers

17D3 Serrated
Washers

Hook Anchor

Dead Load Anchor

Once the units are set and final
adjustments are made, turn the
washer so that the serrations
align and secure anchor bolts.

17D4 Slab
Anchor

Once final adjustments have been
made, match drill the hook anchor
and install the pin screw to lock the
lateral position of the frame unit.

Once final adjustments have been

made, match drill the hook anchor

and install the pin screw to lock the

lateral position of the frame unit.

Advertising
This manual is related to the following products: