Series 8700 / 8800 Unitized Curtain Wall Installation Instructions

Figure 120

6. Refer to “Section 10 - Setting Typical Intermediate Units” on pages 45 - 51 when installing corner units at intermediate floor slab locations. The inside 90°

corner anchor condition is shown below. See Figure . The outside 90° corner anchor condition is shown in Figure .

Section 11 - Setting Assembled (One Piece) Corner Units

Figure 119

Lifting Lug

Lifting Lug

17D4 Slab
Anchor

17D3 Serrated
Washers

Hook Anchor

Unit dead load anchor

17D3 Serrated
Washers

Hook Anchor

Unit dead load anchor

17D4 Slab
Anchor