EFCO 8800 Installation Instructions User Manual

Page 50

Advertising
background image

EFCO 2009

Page 50

Series 8700 / 8800 Unitized Curtain Wall Installation Instructions

Section 10 - Setting Typical Intermediate Units

Figure 110

22. Compare the unit to established bench marks and move the unit side to side to position it laterally to the required location. At the stacked mullions the

mullion width should be 3”.

23. Adjust the unit for plumb, parallel to the plane of the wall, by sliding the slab anchor forward or backward until the unit is plumb. See Figure 110.
24. Rotate the serrated washers where the serrations align with the serrations in the slab anchor and secure the anchor bolts.
25. Tighten the jack bolts of the mullion anchors just tight enough so that the shims at the stack joint below can be removed and the unit stays in the nominal

position. See Figure 103 on page 47. Remove the shims between the sill and the starter sill that were applied in step 16.

17D4 Slab

Anchor

Hook Anchor

Once the units are set, and final
adjustments are made, turn the
washer so that the serrations
align and secure anchor bolts.