EFCO 8800 Installation Instructions User Manual

Page 59

Advertising
background image

EFCO 2009

Page 59

Series 8700 / 8800 Unitized Curtain Wall Installation Instructions

4. Insert a backer rod into the reveal on the end of the starter sill. Recess the backer rod into the cavity of the reveal at a minimum of 1/4”. Seal off the end of

cavity with sealant and marry it into the end dam sealant. See Figure 127.

5. Special care is needed to ensure that the end dam is properly sealed and marries into the perimeter sealant correctly at the jamb to sill condition. Place a

piece of backer rod between the end dam and the jamb. The backer rod will run from the front face of the end dam to the engagement leg. Run a bead
sealant between the end dam and the jamb. Tool the sealant to create a water tight seal between the end dam and the frame. See Figures 128 & 129.

6. Place backer rod and run perimeter sealant at the sill and jamb. See Figure 129. Ensure that the sealants all marry together to create a water tight seal.

Section 13 - Applying Typical Perimeter Seals

Note:

Jamb condition not
shown for clarity.

Insert a piece of backer rod

into the reveal cavity and

apply sealant to create a

watertight seal.

Tool sealant

between the jamb

and end dam.

Tool sealant so

that all lines of

sealant marry

together.

Figure 128

Figure 127

Figure 129

Advertising
This manual is related to the following products: