3 south bridge sub-menu – Kontron AT8060 User Manual

Page 112

Advertising
background image

Software Setup

97

AT8060

www.kontron.com

5.1.5.3

South Bridge sub-menu

Feature

Option

Description

Help text

PCH Information

Subtitle

Name

Display only

PCH Name

Stepping

Display only

PCH Stepping

SB Chipset Configuration

Subtitle

PCH Compatibility RID

Disabled, Enabled

Support for PCH

Compatibility Revision

ID (CRID) Functionality.

SMBus Controller

Disabled, Enabled

Enabled/Disabled SMBus

Controller.

Periodic SMI

Disabled, Enabled

Enabled/Disabled

Periodic SMI.

Restore AC Power Loss

Power Off, Power On,

Last State

Specify what state to go

to when power is re-

applied after a power

failure (G3 state).

SLP_S4 Assertion Stretch

Enable

Disabled, Enabled

Enabled/Disabled

SLP_S4# Assertion

Stretch.

SLP_S4 Assertion Width

1-2 Seconds, 2-3

Seconds, 3-4

Seconds, 4-5

Seconds

Select a minimum

assertion width of the

SLP_S4# signal.

Deep Sx

Disabled, Enabled in

S5(Battery),

Enabled in S5,

Enabled in S4 and

S5(Battery),

Enabled in S4 and S5

Deep Sx configuration.

NOTE:Mobile platforms

support Deep S4/S5 in

DC only and Desktop

platforms support Deep

S4/S5 in AC only.

Disable SCU devices

Disabled, Enabled

Enable/Disable Patsburg

SCU devices.

Onboard SAS Oprom

Disabled, Enabled

Enabled/Disabled

onboard SAS option rom.

When Enabled is

selected (to access SAS

disks on the RTM),

Disable SCU devices

feature must be set to

Disabled.

Onboard SATA RAID Oprom

Disabled, Enabled

Enabled/Disabled

onboard SATA RAID

option rom. When

Enabled is selected (to

access SATA disks on the

RTM), Disable SCU

devices feature must be

set to Disabled..