52

AT8060

www.kontron.com

76

Bios Flash 1

Discrete

Bios Flash 1
Sensor type = 1Eh Boot Error
Event Reading type code = 6Fh Sensor Specific
Only offset 3 is used
See IPMI v2.0 table 42-3, Sensor type code 1Eh for sensor

definition

77

ACPI State

Discrete

Advance Configuration and Power Interface State
Sensor type = 22h System ACPI Power State
Event Reading type code = 6Fh Sensor specific
Only offset 0,4,5,10,11,12,14 are used.
See IPMI v2.0 table 42-3, Sensor type code 22h (ACPI Power

State) for sensor definition

78

IPMI Watchdog

Discrete

IPMI Watchdog (payload watchdog)
Sensor type = 23h Watchdog 2
Event Reading type code = 6Fh Sensor specific
Only offset 0,1,2,3,8 are used
See IPMI v2.0 table 42-3, Sensor type code 23h (Watchdog 2) for

sensor definition

79

Health Error

Discrete

General health status, Aggregation of critical sensor
This list is flexible and could be adjust based on customer

requirements
Sensor type = 24h Platform Alert
Event Reading type code = 03h Digital Discrete
Only offset 0,1 are used
See IPMI v2.0 table 42-3, Sensor type code 24h for sensor

definition

80

IPMB0 Link State

Discrete

IPMB-0 fault detection sensor
Sensor type = F1h PICMG Physical IPMB-0
Event Reading type code = 6Fh Sensor specific
See PICMG 3.0 R3.0 Table 3-69, “Physical IPMB-0 event message”

81

FRU0 IPMBL State

Discrete

IPMB-L branch from FRU0 fault detection sensor
Sensor type = C3h OEM (Kontron OEM IPMB-L link state)
Event Reading type code = 6Fh Sensor specific
Only offset 2 and 3 are used
See OEM table, Sensor type code C3h (Kontron OEM IPMB-L Link

State) for sensor definition