Kontron AT8060 User Manual

Page 68

Advertising
background image

53

AT8060

www.kontron.com

82

FRU1 IPMBL State

Discrete

IPMB-L branch from FRU1 fault detection sensor
Sensor type = C3h OEM (Kontron OEM IPMB-L link state)
Event Reading type code = 6Fh Sensor specific
Only offset 2 and 3 are used
See OEM table, Sensor type code C3h (Kontron OEM IPMB-L Link

State) for sensor definition

83

FRU2 IPMBL State

Discrete

IPMB-L branch from FRU2 fault detection sensor
Sensor type = C3h OEM (Kontron OEM IPMB-L link state)
Event Reading type code = 6Fh Sensor specific
Only offset 2 and 3 are used
See OEM table, Sensor type code C3h (Kontron OEM IPMB-L Link

State) for sensor definition

84

CPU0 Status

Discrete

Processor 0 Status
Sensor type = 07h Processor
Event Reading type code = 6Fh Sensor Specific
Only offset 0,1,5 are used
See IPMI v2.0 table 42-3, Sensor type code 07h for sensor

definition

85

CPU1 Status

Discrete

Processor 1 Status
Sensor type = 07h Processor
Event Reading type code = 6Fh Sensor Specific
Only offset 0,1,5 are used
See IPMI v2.0 table 42-3, Sensor type code 07h for sensor

definition

86

FRU Over Icc

Discrete

FRU Over Current Sensor
Sensor type = CBh OEM (Kontron OEM FRU Over Current)
Event Reading type code = 03h Digital Discrete offset 0,1 are

used,
-see OEM table, Sensor type code CBh (Kontron OEM FRU

Overcurrent) for sensor definition

87

FRU Sensor Error

Discrete

FRU Error during external FRU Sensor discovery
Sensor type = CCh OEM (Kontron OEM FRU sensor error)
Event Reading type code = 03h Digital Discrete offset 0,1 are

used,
-see OEM table, Sensor type code CCh (Kontron OEM FRU sensor

error) for sensor definition

Advertising