Kontron AT8060 User Manual

Page 71

Advertising
background image

56

AT8060

www.kontron.com

102

SEL Time Set

Discrete

Specify when SEL time change
Sensor type = 12h System Event
Event Reading type code = 6Fh Sensor specific
Only offset 5 is used
See IPMI v2.0 table 42-3, Sensor type code 12h for sensor

definition

103

Jumper Status

Reflects on-board jumper presence
Sensor type = D3h OEM (Kontron OEM Jumper Status)
Event Reading type code = 6Fh Sensor specific, offsets 0 to 14 are

used
See OEM table, Sensor type code D3h (Kontron OEM Jumper

Status) for sensor definition

104

ME Availability

Discrete

Provides status on the chipset Management Engine
Sensor type = 28h Management Subsystem Health
Event Reading type code = 0Ah Generic Discrete, offset 2,6,8 are

used
See IPMI v2.0 table 42-3, event reading type code 0Ah for sensor

definition

105

LAN Base 0 Link

Discrete

Base Interface 0 link status
Sensor type = 27h LAN
Reading type code = 6Fh Sensor Specific
Only offset 0,1 are used
See IPMI v2.0 table 42-3, Sensor type code 27h for sensor

definition

106

LAN Base 1 Link

Discrete

Base Interface 1 link status
Sensor type = 27h LAN
Reading type code = 6Fh Sensor Specific
Only offset 0,1 are used
See IPMI v2.0 table 42-3, Sensor type code 27h for sensor

definition