2 system, 1 system information, 2 lan info – Kontron AT8060 User Manual

Page 44: 3 system tree, 3 sensor, 1 reading, 4 event log, 5 control, 1 remote power / reset, System

Advertising
background image

29

AT8060

www.kontron.com

4.3.2

System

4.3.2.1

System Information

Once connected to the Web Management Interface, the first page displayed is the System Information. The
current component versions and board information such as serial numbers and part numbers are displayed
on this page

4.3.2.2

LAN Info

This page displays information on the IPMC LAN interfaces configuration. This configuration can be updated
using this interface.

4.3.2.3

System Tree

This page list the IPMB addresses of the boards connected in the chassis.

4.3.3

Sensor

4.3.3.1

Reading

This page displays all board sensor readings. Values can be manually refreshed. Refer to Table 4-20 for a list
of sensors for this board.

4.3.4

Event Log

4.3.4.1

Reading

This page displays System Event Log (SEL) information and the event list. The SEL can have up to 5119
entries, and it can be cleared or refreshed manually. Using the arrows under the table allows browsing
through the event list.

4.3.5

Control

4.3.5.1

Remote Power / Reset

This page displays the current Hot-Swap state, Power state and power level of the board and its managed
FRUs. It also allows performing power down, graceful shutdown, power cycle, power up and reset of all the
FRUs.

Note:

Configuration of the LAN interface being in use to access the Web Management Interface may lead
to loss of connection.

Note:

Power up of FRU0 is not supported, as the Web Management Interface is not accessible when it is
powered down.

Advertising