Ver Change IPMC

Discrete

IPMC Firmware Change Detection
Sensor type = 2Bh Version Change
Event Reading type code = 6Fh Sensor specific
See IPMI v2.0 table 42-3, Sensor type code 2Bh for sensor

definition

96

Ver Change FPGA

Discrete

FPGA Firmware Change Detection
Sensor type = 2Bh Version Change
Event Reading type code = 6Fh Sensor specific
See IPMI v2.0 table 42-3, Sensor type code 2B for sensor

definition

97

Ver Change BIOS

Discrete

BIOS Firmware Change Detection
Sensor type = 2Bh Version Change
Event Reading type code = 6Fh Sensor specific
See IPMI v2.0 table 42-3, Sensor type code 2Bh for sensor

definition

98

EventRcv ComLost

Discrete

Detects communication with the event receiver (ShMc)
Sensor type = 1Bh Cable/Interconnect
Event Reading type code = 03h Digital Discrete
See IPMI v1.5 table 36.2 and table 36.3 for sensor definition

99

IPMC Reboot

Discrete

IPMC reboot detection
Sensor type = 24h Platform Alert
Event Reading type code = 03h Digital Discrete
Only offset 0,1 are usedà
See IPMI v2.0 table 42-3, Sensor type code 24h for sensor

definition

100

IPMC Storage Err

Discrete

Management sub-system health: non volatile memory error
Sensor type = 28h Management Subsystem Health
Event Reading type code = 6Fh Sensor specific
Only only offset 1 is used
See IPMI v2.0 table 42-3, Sensor type code 28h for sensor

definition

101

IPMC SEL State

Discrete

Specify if the status of the SEL (Cleared/Almost Full/Full)
Sensor type = 10h Event Logging Disable
Event Reading type code = 6Fh Sensor specific
Only offset 2,4,5 are used
See IPMI v2.0 table 42-3, Sensor type code 10h (Event Log

Disable) for sensor definition