2 power limit options sub-menu – Kontron AT8060 User Manual

Page 116

Advertising
background image

Software Setup

101

AT8060

www.kontron.com

5.1.6.2

Power Limit options sub-menu

Feature

Option

Description

Help text

Power Limit options

Subtitle

Power Limit

Activated,

Deactivated

Activate/Deactivate

Power Limit option

Power Limit Value

Numeric

Set the Power Limit

threshold value

Exception Action

No action, Hard

Power Off System

and log event to SEL,

Log event to SEL

only

Exception action taken if

the Power Limit is

exceeded and cannot be

controlled within the

Correction time limit

Correction Time Limit

Numeric

Maximum time in

miliseconds taken to

limit the power after the

platform power has

reached the power limit

before the Exception

Action will be taken

Statistics Sampling period

Numeric

Statistics sampling

period in seconds