Kontron AT8060 User Manual

Page 61

Advertising
background image

46

AT8060

www.kontron.com

34

Vcc +1.2V SUS

Threshold

Voltage on board 1.2V suspend (management) power supply

(Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event

35

Vcc +1.0V SUS

Threshold

Voltage on board 1.0V suspend (management) power supply

(Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event

36

Vcc +0.75V SUS

Threshold

Voltage on board 0.75V suspend (management) power supply

(Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event

37

Vcc +1.5V

Threshold

Voltage on board 1.5V payload power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event

38

Vcc +1.2V

Threshold

Voltage on board 1.2V payload power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event

39

Vcc +1.1V

Threshold

Voltage on board 1.1V payload power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event

40

Vcc VCORE 0

Threshold

Voltage on board CPU0 Vcore payload power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event

41

Vcc VTT CPU 0

Threshold

Voltage on board CPU0 VTT payload power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event

42

Vcc VDDQ CPU 0

Threshold

Voltage on board CPU0 VDDQ payload power supply (Volts)
Sensor type = 02h voltage
Event Reading type code = 01h threshold based
See IPMI v2.0 table 42-2 for threshold based event

Advertising