320IS Installation Manual - Installation

9

2.3

Hazardous Area Installation of the 320IS

2.3.1

The following information is provided to help the installer with the correct installation of the

320IS

system.

See Figure 2-1 below for a diagram of a typical intrinsically safe system.

Figure 2-1. Intrinsically Safe System Diagram

2.3.2

Power Supply to Indicator

Do not, under any circumstances, connect or disconnect the DC wire from the indicator while the AC
power is applied to the power supply. This will cause the power supply fuse to blow.

The indicator should be powered by an FM-approved Rice Lake power supply or alternatively from an external

battery pack. The power requirements of the

320IS

are as follows:

Minimum input voltage: 5.8 V

Maximum input voltage: 7.9 V

Peak current consumption: 190 mA

Average input current (with four load cells): 140 mA

The DC power cable should be attached to connector CN1 (see Table 2-1). Care must be taken to wire CN1 with

the correct DC polarity. See Section 2.4 on page 10 for information on cabling through metal cord grips.

CN1 Pin

Function

Wire Color

1

+ Voltage (5.8 – 7.9 V)

Green

2

Ground (V–, Common)

Brown

Table 2-1. DC Power Supply Connections

Junction

Box

(Optional)

AC Power

Supply

(Intrinsically

Safe Output)

FM-Approved

Load Cells

(up to 4–350Ω)

Battery

(Optional)

I/O Module

(Optional)

Battery

Charger

(Optional)

Load Cell

Input

Fiber Optic

VDC

115/230VAC

WARNING