5 normal mode commands, Normal mode commands, Gh 5-12 for more information – Rice Lake Intrinsically Safe User Manual

Page 47

Advertising
background image

320IS Installation Manual - EDP Commands

41

5.1.5

Normal Mode Commands

The serial transmit weight data commands (see Table 5-13) transmit data to the EDP port on demand. The SX and

EX commands are valid only in normal operating mode; all other commands are valid in either setup or normal

mode.

Command

Description

Values

AO2.SOURCE

Analog output source

GROSS, NET

AO2.OFFSET

Zero offset

0%, 20%

AO2.ERRACT

Error action

FULLSC, HOLD, ZEROSC

AO2.MIN

Minimum value tracked

0–999 990

AO2.MAX

Maximum value tracked

0–999 990

AO2.TWZERO

Zero calibration

0–65535

AO2.TWSPAN

Span calibration

0–65535

Table 5-12. ALGOUT 2 EDP Commands

Command

Description

Response Format

SX

Start EDP streaming

OK or ??

EX

Stop EDP streaming

OK or ??

RS

Reset system

XG

Transmit gross weight in displayed units

nnnnnn UU

where nnnnnn is the weight value, UU is the units.

XN

Transmit net weight in displayed units

XT

Transmit tare weight in displayed units

XG2

Transmit gross weight in non-displayed units

XN2

Transmit net weight in non-displayed units

XT2

Transmit tare weight in non-displayed units

XE

Query system error conditions

xxxxx yyyyy

See Section 7.1.2 on page 46 for detailed information about
the XE command response format.

XA

Transmit accumulation value

UID

set unit ID

nnnnnn

CONSNUM

Set consecutive number

Table 5-13. Normal Mode EDP Commands

Advertising