8 version menu, Version menu – Rice Lake Intrinsically Safe User Manual

Page 38

Advertising
background image

32

320IS Installation Manual

3.3.8

Version Menu

The VERS menu is used to check the software or hardware version installed in the indicator. There are no

parameters associated with the Version menu; when selected, the indicator displays the installed software or

hardware version number.

Figure 3-9. Version Menu

ALG OUT Menu

Parameter

Choices

Description

ALOUT1
ALOUT2

SOURCE
OFFSET
ERRACT
MIN
MAX
TWZERO
TWSPAN

Specifies settings for source, offset, error action, minimum, maximum, tweak zero and tweak
span value used by the analog outputs.

Level 2 submenus

SOURCE

GROSS
NET

Specifies the source tracked by the analog output.

OFFSET

0%
20%

Zero offset. Selects whether the analog output supplies voltage (0-5 V, ±5 V, ±10 V) or current
(4–20 mA) output. Select 0% for 0-5 V, ±5 V, ±10 V output, 20% for 4–20 mA output.

ERRACT

FULLSC
HOLD
ZEROSC

Error action. Specifies how the analog output responds to system error conditions.
Possible values are:

FULLSC

Set to full value

HOLD:

Hold current value

ZEROSC: Set to zero value

MIN

000000
number

Specifies the minimum weight value tracked by the analog output. Specify a weight value (in
primary units) in the range 000000–999 990.

MAX

010000
number

Specifies the maximum weight value tracked by the analog output. Specify a weight value (in
primary units) in the range 0–999 990.

TWZERO

65300
number

Tweak zero. Adjust the analog output zero calibration. Use a multimeter to monitor the analog
output value. Press and hold

or

to adjust the output. Press

to save the new value.

NOTE: Default value becomes 11000 if OFFSET is set to 20%.

TWSPAN

65300
number

Tweak span. Adjust the analog output span calibration. Use a multimeter to monitor the analog
output value. Press and hold

or

to adjust the output. Press

to save the new value.

NOTE: Default value becomes 54900 if OFFSET is set to 20%.

Table 3-8. Analog Output Menu Parameters

SOFTWR

Software Version

I/O Module Version

XXXXXXX

XXXXXXX

XXXXXXX

XXXXXXX

VERS

ALGOUT

DIG IN

PROGRM PFORMT

SERIAL

CALIBR

CONFIG FORMAT

I/OMOD

Displays “No Ver”

if no I/O Module is

connected

Advertising
This manual is related to the following products: