320IS Installation Manual

TEST Menu

Function

Description

A/DTST

Display A/D test
Press and hold ENTER key to display raw counts from A/D converter.

ADCAL-

(ADOFFS)
A/D calibration functions must only be used by qualified service personnel. Improper A/D calibration may render
indicator unusable.

ADCAL+

(ADGAIN)

A/D calibration functions must only be used by qualified service personnel. Improper A/D
calibration may render indicator unusable.

D/I 1

Display digital input 1
Press and hold ENTER key to show status of DIGIN1 (DIN1=1 or DIN1=0).

D/I 2

Display digital input 2
Press and hold ENTER key to show status of DIGIN2 (DIN2=1 or DIN2=0).

D/I 3

Display digital input 3
Press and hold ENTER key to show status of DIGIN3 (DIN3=1 or DIN3=0).

D/I 4

Display digital input 4
Press and hold ENTER key to show status of DIGIN4 (DIN4=1 or DIN1=0).

D/O 1

Set digital output 1 to High
Press and hold ENTER key to set digital output 1 to High (DO1=HI).

D/O 2

Set digital output 2 to High
Press and hold ENTER key to set digital output 2 to High (DO2=HI).

D/O 3

Set digital output 3 to High
Press and hold ENTER key to set digital output 3 to High (DO3=HI).

D/O 4

Set digital output 4 to High
Press and hold ENTER key to set digital output 4 to High (DO4=HI).

A/O 1

Set analog output 1 to full scale
Press and hold ENTER key to set analog output 1 to its full-scale value.

A/O 2

Set analog output 2 to full scale
Press and hold ENTER key to set analog output 2 to it full-scale value.

DEFLT

Default parameters
Press setup switch and ENTER key at the same time to reset configuration and calibration parameters to factory
default values. Load cells must be recalibrated before using the indicator (see Section 4.0 on page 33).

XMTEDP

Transmit “U” through EDP port
Press and hold ENTER key to send ASCII “U” characters (decimal 85) from the serial port.

XMTPRN

Transmit “U” through PRN port
Press and hold ENTER key to send ASCII “U” characters (decimal 85) from the serial port.

ECHO R

Echo received characters
Press and hold ENTER key to view a string of characters terminated with a carriage return <CR> received at
either serial port.

Table 7-9. Test Menu Functions