14

320IS Installation Manual

9. Wire cable to connector CN3.

Figure 2-5. Cable Connections

2.4.5

Load Cells

To attach cable from a load cell or junction box, use six-position connector in parts kit. See Section 2.4 on page 10

for information on cabling through metal cord grips.
Wire the load cell cable from the load cell or junction box to connector CN3 as shown in Figure 2-6. If using 6-wire

load cell cable (with sense wires), remove jumpers J1 and J2 before installing connector CN3. For four-wire

installation, leave jumpers J1 and J2 on.
When connections are complete, reinstall connector CN3 on the board and use two cable ties to secure the load cell

cable to the inside of the enclosure.

Figure 2-6. CN3 Load Cell Connections

Load cell
connector

Power cable connector

Green = +Voltage

Brown = Return

125mA fully –
encapsulated
fuses
F1 & F2

Blue pptical
output

Black optical
input

Ferrite cores

C h a s s i s
ground

Sense jumpers
J1 & J2

1 2 3 4 5 6

CN3

-Excitation

-Sense

-Signal

+Signal

+Sense

+Excitation

Advertising
This manual is related to the following products: