2 status messages, 1 using the p edp command, 2 using the zz edp command – Rice Lake Intrinsically Safe User Manual

Page 53: Using the p edp command, Using the zz edp command, Bed in table 7-2, Table 7-2

Advertising
background image

320IS Installation Manual - Appendix A

47

7.2

Status Messages

Two EDP commands, P and ZZ, can be used to provide status about the indicator. These commands are described

in the following sections.

7.2.1

Using the P EDP Command

The P EDP command returns the current displayed weight value to the EDP port, along with the units identifier. If

the indicator is in an underrange or overload condition, the weight value is replaced with ^^^^^^ (overload) or

_ _

_ _ _ _

(under range).

7.2.2

Using the ZZ EDP Command

The ZZ EDP command can be used to remotely query which annunciators are currently displayed on the indicator

front panel. The ZZ command returns the currently displayed weight and a decimal number representing the LED

annunciators currently lit. The format of the returned data is;

wwwwww uu zzz

where

wwwwww uu

is the current displayed weight and units,

zzz

is the annunciator status value (see Table 7-3). If

more than one annunciator is lit, the second number returned is the sum of the values representing the active

annunciators.

Error Code

Description

Binary Value

1

EEPROM physical error

0000 0000 0000

0001

2

Virgin EEPROM

0000 0000 0000

0010

4

Parameter checksum
error

0000 0000 0000

0100

8

Load cell calibration
checksum error

0000 0000 0000

1000

16

A/D calibration
checksum error

0000 0000 0001

0000

32

Print format checksum
error

0000 0000 0010

0000

64

Internal RAM checksum
error

0000 0000 0100

0000

128

External RAM error

0000 0000 1000

0000

256

No optical
communication

0000 0001 0000

0000

512

A/D physical error

0000 0010 0000

0000

1024

A/D reference error

0000 0100 0000

0000

2048

Count error

0000 1000 0000

0000

4096

Low battery

0001 0000 0000

0000

8192

Display error

0010 0000 0000

0000

16384

A/D underrange

0100 0000 0000

0000

32768

Overflow

1000 0000 0000

0000

Table 7-2. Error Codes Returned on XE Command