67

17. COMMANDS

17-1 Command List

Commands to query weighing data

C Cancels

the

S or SIR command.

Q

Requests the weighing data immediately.

S

Requests the weighing data when stabilized.

SI

Requests the weighing data immediately.

SIR

Requests the weighing data continuously.

E

SC

P

Requests the weighing data when stabilized.

Note: The “Q” and “SI” commands, the “S” and “

E

SC

P” commands behave the same.

Commands to control the balance

CAL

Same as the CAL key.

MCL

Deletes all data in memory.

MD:nnn

Deletes weighing data with the data number nnn.

OFF

Turns the display off.

ON

Turns the display on.

P

Same as the ON:OFF key

PRT

Same as the PRINT key

R

Same as the RE-ZERO key

SMP

Same as the SAMPLE key.

U

Same as the MODE key

T

Same as the RE-ZERO key

Z

Same as the RE-ZERO key

E

SC

T

Same as the RE-ZERO key

Note: The “R”, “T”, “Z” and “

E

SC

T” commands behave the same.

Commands to control the memory function

?MA

Outputs all data in memory.

?MQnnn

Outputs weighing data with the data number nnn.

?MX

Outputs the number of weighing data in memory.

MCL

Deletes all data in memory.

MD:nnn

Deletes weighing data with the data number nnn.

UN:mm

Changes the unit mass stored in memory with the number of mm (01-20).

?UN

Outputs the unit mass number of the selected unit mass.

UW:

∗∗∗. ∗∗ g

Sets the unit mass value. e.g.,UW:+0.123 g (to set the unit mass to

0.123 g: represents a space.)

?UW

Outputs the unit mass value of the selected unit mass number.

?ID

Requests the ID number.

?SN

Requests the serial number.

?TN

Requests the model name.

Commands to control the comparator function

HI:

∗∗∗. ∗∗ g

Sets the upper limit value. e.g.,HI:+2.34 g (to set the upper limit

value to 2.34 g: represents a space.)

LO:

∗∗∗. ∗∗ g

Sets the lower limit value. e.g.,LO:+1.23 g (to set the lower limit

value to 1.23 g: represents a space.)

?HI

Outputs the upper limit value.

?LO

Outputs the lower limit value.

Notes
“nnn” and “mm” indicate, respectively, three-digit and two-digit numerical values.

E

SC

: 1Bh in ASCII code

Before transmitting a command, add the terminator (<CR><LF> or <CR>), that is specified in the
“Terminator (
Crlf)” parameter of “Serial interface (5if)” in the function table, to the command.
To use a command to control the comparator function, set the “Input method (
Cpin)” parameter to “0” or “1”.