Rice Lake TradeRoute HL Series - Low Profile Installation and Setup for Models from 2011 and Older 128406 User Manual

Page 12

Advertising
background image

9

10. Attachment of Container to Scale

Once the scale modules are attached to the truck frame, the container can be attached
to the scale.

Mounting brackets must be attached to the container to bolt the container to the scale.
Mounting hole dimensions are shown in the following figures. Rice Lake Weighing
Systems recommends the following bolt sizes for attaching the container to the scale.

System Size Hole Drill Size

Bolt Size

Torque Spec (ft.-lbs.)

5K or 10K

3/4”

5/8” Grade 8

70 – 90

15K

7/8”

3/4” Grade 8

90 – 110

Measure distance D from module to module to determine distances between mounting
brackets on the container. All hole dimensions must be

1/16”.

IMPORTANT: Bolts shown below are used for shipping and

keeping the load cell assemblies aligned during installation. They
must be removed as soon as the container is attached to the scale

and before testing hydraulics.

Figure 6 - Mounting Hole Dimensions

Advertising