Rice Lake TradeRoute HL Series - Low Profile Installation and Setup for Models from 2011 and Older 128406 User Manual
Page 34
31
EXAMPLE: OB30L-F3 System
Balancing Weights
English = 5000 lb.
Metric = 2000 KG
Graduations
English = 5 lb.
Metric = 2 KG
First Loading
English Units (lbs.)
Load Cell
Metric Units (kg)
M2000 Reading
M2000 Reading
Start
Loaded
Unloaded
Start
Loaded
Unloaded
0
4995
0
1
0
1998
0
0
4990
0
2
0
1996
0
0
5005
0
3
0
2002
0
From the above results, it can be seen that cells 1 and 3 must be adjusted down to read
4990 lbs. (1996 kg in the metric example). First, the trimmer for cell 1 is turned
clockwise to bring the reading down (step 6(c)).
Second Loading
English Units (lbs.)
Load Cell
Metric Units (kg)
M2000 Reading
M2000 Reading
Start
Loaded
Unloaded
Start
Loaded
Unloaded
0
4990
0
1
0
1996
0
2
3
Next, the trimmer for cell 3 is turned clockwise to bring its reading down. Because this
cell is being adjusted by three graduations, the procedure in 6(d) should be followed,
adjust cell 3 down to 4985 lbs. (1994 kg in the metric example) and check for a zero
shift.
Third Loading
English Units (lbs.)
Load Cell
Metric Units (kg)
M2000 Reading
M2000 Reading
Start
Loaded
Unloaded
Start
Loaded
Unloaded
1
2
0
4985
-5
3
0
1994
-2
The unloaded reading is found to be –5 lb (-2 kg), indicating a zero shift. The scale must
therefore be re-zeroed, and cell 3 checked again.