Performing a pre-installation check, Locating the system, Power cord location – Wine Guardian Through-the-Wall Wine Cellar Cooling Systems 50Hz (WG25) - Manual User Manual

Page 19

Advertising
background image

19

 Where to locate the unit? It can be mounted flush with the racking or flush with

the wall on the wine cellar side.

 How to mount the unit? A mounting EasyMount™ kit is supplied.

 Locate the electrical power outlet close to the unit, in cellar or out. Do not use

an extension cord!

 Factory supplied power cord on condenser side of the unit. It is preferred to be

on the condenser side of the unit, the cord can be moved to accommodate wine
cellar side if need be.

 Does the condenser heat exhaust need to be ducted away? An optional kit is

available.

 Where to locate the thermostat, if remote interface control is ordered?

Thermostat should be located midpoint on a wall within the wine cellar and
provide sufficient access and exposure to airflow.

 How to install the drain line. Run to an open floor drain, container, or

condensate pump.

 Are all the parts here to complete the installation? Installation sleeve, gasket,

sealant fasteners

Performing a Pre-installation Check

 Check for the properly sized breaker as dictated by the system rating plate data.

Locating the System
Wine Guardian systems are typically installed at the user’s eye level for ease of operation. The
Through-the-Wall system discharges warm air from its condenser end so this should be
considered when determining the location for the system. Locating the system adjacent to a
mechanical room or in close proximity to an exterior wall may be required if ducting the warm
condenser air is being considered. The warmer condenser air can be ducted up to 4.5 meters
away. Be sure to install wire nuts onto the black and white wire leads at the condenser end, once
the cord is removed.

Power Cord Location

As previously noted, the power cord is factory wired on the
condenser side of the system. If you require the cord on the wine
cellar side for plugging into an available outlet, this can be
accomplished by removing the 3-wire leads (ground included) and
moving the cord with connector to the opposite side control bracket
and wire nutting the black and white wires to the factory supplied
leads. The wires must have the terminations cut off and stripped

first. Then screw the ground lead to the hole supplied in the control bracket.