Step 3, Step 4, Step 5 – Wine Guardian Through-the-Wall Wine Cellar Cooling Systems 50Hz (WG25) - Manual User Manual

Page 21: Step 6

Advertising
background image

21

Step 3

Slide the EasyMount™ sleeve through the wall penetration so that the
flanged area of the sleeve sits flush with the surface of the wall. Ensure
the EasyMount™ sleeve is level and plumb prior to fastening to the
existing studs.









CAUTION

RISK OF PERSONAL INJURY OR DAMAGE TO EQUIPMENT

Flange side of the sleeve must be mounted on side of wall you intend to have the WG flush

mounted.

Step 4

Fasten the EasyMount™ sleeve to the wall studs through the six (6) pre-
drilled holes located on either side of the EasyMount™ sleeve. Start by
inserting a wood screw into the lower pre-drilled holes on both sides of the
sleeve, and tighten until snug. Do not over tighten. Then insert screws into
the upper pre-drilled holes on both sides of the sleeve, continue to middle
set of holes. Ensure screws are flush with wall sleeve inside surface. Do
not over tighten.

Step 5

Slide the Wine Guardian Through-the-Wall system through the
EasyMount™ sleeve to the desired depth. Please note the Through-the-
Wall system must be slid so that the power cord side is last, not first, to
enter the sleeve. Do not slide the system past the desired flush mounting
point.

Step 6

Seal joint between EasyMount™ sleeve and Wine Guardian system on
the flange side of system with a latex caulk to ensure a tight seal and
prevent the system from horizontal movement. After caulking, add the
kit supplied self adhesive insulate strips tight to the chassis and cover the
wall sleeve flanges to prevent possible sweating.

IMPORTANT

The Installation Sleeve must be installed level within the wall opening to provide proper
operation of the Wine Guardian system. Failure to do so may result in improper drainage,
excessive ware, vibration and noise.

Advertising
This manual is related to the following products: