Other miscellaneous problems, Problems controlling cellar humidity – Wine Guardian Through-the-Wall Wine Cellar Cooling Systems 50Hz (WG25) - Manual User Manual

Page 41

Advertising
background image

41

Humidity too high when unit is not
running

Possible Cause

Solution

System needs to run to dehumidify

Lower room temperature setpoint. Seal
openings around doors (gasket and sweep)

Humidity too high when unit is running
and cooling

Possible Cause

Solution

Too much moisture in cellar

Poor vapor barrier installation
Humidifier malfunction refer to the humidifier
instructions

Add dehumidifier to surrounding space

Other Miscellaneous Problems

System is leaking water

Possible Cause


Solution

Condensate pan plugged

Unit not level

Remove blockage and clean

Level with shims

System is running properly, but the sounds
of unit is objectionable

Possible Cause

Solution

Noise is from airflow

Duct airflow from condenser to outdoors


Problems Controlling Cellar Humidity