Wiring the System for Power

WARNING

ELECTRICAL SHOCK HAZARD

The electrical outlet and wiring installation must meet the national and local building codes.

DO:

 Match the electrical outlet to the plug provided on the Wine Guardian.

 Provide dedicated circuit and wiring for the system.

 Match the wiring and breaker size to the rated load as shown on the serial

plate and in this guide. See sample serial plate illustration below.









DO NOT:



DO NOT MODIFY THE PLUGS IN ANY WAY!



Do not use extension cords.




Plug the system into the wall outlet. Gently pull on the plug to make
sure it is tight.

Electrical Plug Configuration


This is the configuration of the factory supplied plug for European
applications. Alterations to this plug for alternative power sources
would require factory approval. LCDI (leakage current detection
interrupter) power cord, which specifies that single phase portable air
conditioning units contain a protection device to reduce the risk of an
arc fault occurring in the power cord. These provide a reliable way to
prevent the risk of fire due to a damaged power cord. They feature

electronic detection to automatically cut off power to the unit when a current leakage condition is
detected in the systems power cord.

Once power is shut off, the device will not be able to be reset until the unsafe current leakage
situation is resolve. Power is restored by the “reset” button on the cord’s power head.

IMPORTANT

The electrical power supply must be 115 volt AC 1 phase 60 cycle, depending on the model

of the system, and cannot vary more than +/- 4% or damage may occur to the unit.

Electrical

240/1/50

Electric Heat Amps (Opt.)

2.1

Locked Rotor Amps

9

Compressor RLA

0.9

Condenser Fan Amps

0.2

Min. Circuit Amps (w/o opt.)

2.9

Evaporator Fan Amps

0.2

Refrigerant

R-134-A

Condensate Heater

N/A

System Charge

256 g

Total Unit Amps (w/o opt.)

1.3

Test Pressure 1896 k Pa

00 1 315-452-7400 * Fax: 00 1 315-452-7420

WG15 is Patent Pending

Model No. WG15

Serial No.

Air Innovations, 7000 Performance Drive, North Syracuse, New York 13212