Starting-up and Operating the

Wine Guardian

Control Settings

The control has been wired and set up in the factory for testing with
default settings. It is an electronic digital thermostat for one-stage
cooling. No additional adjustments should be necessary except
adjusting the cellar temperature to your preference. If additional
adjustments or changes are necessary, please refer to the
configuration settings section in this manual.

Controller Functions

ON/OFF – The ON/OFF button will be used to turn the system on or off. When set to the off
mode the control will not allow any of the outputs to energize effectively locking the system
out. It will not allow any outputs to energize until the system is turned on with the ON/OFF
button. It should be noted that high voltage will still be present at the main control board when
the system is set to off even though the control will not allow it to switch to the outputs.

UP Arrow – The UP arrow will allow the user to increase settings.

DOWN Arrow – The DOWN arrow will allow the user to decrease settings.

MODE – The MODE button will be used to select between HEAT, COOL and AUTO MODE,
as well as entering the configuration settings. Holding the MODE button for 5 seconds will
enter configuration mode. Once in configuration mode the user can adjust settings by pressing
the UP or DOWN arrows. Pressing the MODE button once will advance to the next
configuration settings. Holding the MODE button for 5 seconds while in configuration mode
will store all changes and exit configuration mode.

For cooling operation only: Cooling is set at 13°C from the factory. This can be changed by
hitting the UP or DOWN arrow, but please refer to configuration settings # 2 and # 3 for
limitations in comparison to the High and Low temperature alarm settings.

For units with optional humidifier controlled by TTW WG: The RH% is factory set at
55%. This can be changed by referring to configurations setting # 6. If no humidifier is
attached, the control will read RH%, but will not be controlling it.

Changing fan operation: The default setting from the factory is “AUTO” fan. If desired it can
be changed to fan “ON” by accessing configuration setting #