3.2 Statox 4120 rack


Statox 4120 Rack must not be installed in hazardous areas. Observe local safety- and installation
regulations.
Protect any cable from tensile strain. The five - and the nine - contact terminals are plugged in. They
can be removed to ease wire connection.

pic.10: Backplane Statox 4120 Rack






Installation instructions:

The signal cable from sensor head to backplane must be shielded. The shield must make good
contact to the ground contact on the backplane as well as to the sensor head metal shield.

Do not remove the conductive silicon bearing of the sensor head housing.

T

he sensor head housing must be installed isolated from ground to avoid ground loops.

The entire system must only be grounded by the mains ground wire.

All control modules must be well connected and secured with the screws.


Connecting the mains cable initiates the system.