Installation

9145ELB NID Hardware User’s Manual

Installing the SFP Module

15

Figure 3-2 Installing the Rack Mount Kit

3.3.2 Horizontal Flat Surface Mounting

The 9145ELB requires at least one inch of unobstructed space around the perimeter for
ventilation. Canoga Perkins recommends a space of 3 to 5 inches be left unobstructed to allow
for SFP module access, cable access, and power connections.

To install the 9145ELB on a flat surface, place the 9145ELB on a secure flat surface such as a
table, a shelf, or a desk within reach of the power and fiber optic cables.

Connect the power and fiber optic cables to the 9145ELB as required.

3.4 Installing the SFP Module

Follow these steps to install the SFP module:

1. Determine which SFP Module(s) is/are required for the user and Network Ports by

referencing the SFP Product Data Sheet.

2. Insert a module into each available port and push firmly to seat the module (

Figure 3-3

).

3. Raise the latch to lock the module in place.