2 measuring receiver input power, Measuring receiver input power – CANOGA PERKINS 9145ELB Network Interface Device Hardware User Manual

Page 46

Advertising
background image

9145ELB NID Hardware User’s Manual

Maintenance

Checking Optical Power Levels

32

3. Connect the other end of the optic test cable to the optical power meter (

Figure 6-1

), wait

two or three minutes for the power reading to stabilize, and read the output power.

4. Add the test cable loss, then record the power level and compare it to the value on the

performance sheet that was included for that transceiver. Measurement tolerance is +/-
0.5 dBm.

5. If the reading is low, repeat the measurement with a different test cable. If the power level

is still not within range, call Canoga Perkins Technical Support.

Figure 6-1 Measuring Transmitter Output Power

6.2.2 Measuring Receiver Input Power

To measure receiver input power (

Figure 6-2

):

1. Connect the transmit fiber to the transmit side of the equipment at the local site.

2. Connect a calibrated optical power meter to the end of the transmit fiber at the remote

site.

3. Measure and record the optical power on the transmit fiber at the remote site. This is the

receiver input power for the transmit fiber from the local site.

4. Connect the transmit fiber to the transmit side of the equipment at the remote site.

5. Connect a calibrated optical power meter to the end of the transmit fiber at the local site.

6. Measure and record the optical power on the transmit fiber at the local site. This is the

receiver input power for the transmit fiber from the remote site.

7. Compare the receiver input power with the sensitivity level listed on the optical

specifications sheet, located in the Client Support Area of the Canoga Perkins web site.
The power level must be within the sensitivity range listed on the data sheet. If not,
contact Canoga Perkins Technical Support.

8. Compare the receiver input power to the receiver’s saturation (overdrive) level shown on

the optical specifications sheet, located in the Client Support Area of the Canoga Perkins

FIBER OPTIC
TRANSMITTER

FIBER OPTIC
RECEIVER

OPTICAL
POWER
METER

-7dBm

λ = 1300 nm

Advertising