2 data interface section leds, Data interface section leds – CANOGA PERKINS 9145ELB Network Interface Device Hardware User Manual

Page 38

Advertising
background image

9145ELB NID Hardware User’s Manual

Operation

LED Indicators

24

4.3.2 Data Interface Section LEDs

Table 4-3. describes the LED indicators for the SPD and ACT LEDs of User Ports. Table 4-4.
describes the LED indicators for Network Ports. Indications apply to both the SFP and UTP
LEDs.

Table 4-3. User Port LED Indicators

LED Name

LED State

Condition

Power (PWR)

Off

Power is off

Green

Power is on

Amber

One power supply failed in a redundant power
supply configuration

Red

One of the board supply voltages has exceeded a
threshold value

LED Name

State

Condition

Speed
(SPD)

Off

10 Mbps (Copper or Twisted Pair Links only)

Auto negotiate

Port disabled

Green

1000 Mbps

Amber

100 Mbps

System Test

Slow Blinking Green* Port enabled but no link

Red

Remote fault (fiber optic links only)

Blinking Red

Invalid/unsupported SFP installed (SFP connectors only)

Link Activity
(LA)

Off

No link

No transmit or receive activity

Port disabled

Green

Link up with full duplex

Blinking Green

Transmit or receive activity in full duplex

Amber

System test

Link up with half duplex

Blinking Amber

Transmit or receive activity in half duplex

Link down but transmitting OAM packets in unidirectional
mode (UTP connectors only)

Blinking Red

Link down but transmitting OAM packets in unidirectional
mode (SFP connectors only)

* Slow blinking green means that the LED toggles between Off and Green approximately once per

second

Advertising