Scale setup, Normal – Elektron Octatrack User Manual

Page 105

Advertising
background image

PATTERNS

93

holding the [TRIG] key of the trig you want to micro edit, then press either the left or right
[ARROW] button.

TRIG COUNT sets the number of times the sample trig should be repeated. Adjust this set-
ting with the up and down [ARROW] keys.

TRIG OFFSET controls where the trig should be placed on the 1/384 step resolution micro
timing grid. Move the trig on the grid by pressing the left and right [ARROW] buttons. A trig
can be nudged both forwards and backwards in time in relation to the step it is placed on.

If a trig placed on the first sequencer step is nudged backwards, it will be acti-
vated at the end of the pattern.

Setting the tempo to 2x in the SCALE SETUP menu will double the resolution of
the micro timing grid.

Micro timed trigs can be quantized in the TRACK TRIG EDIT menu. Read more on
page 87
.

SCALE SETUP

Here the general length and timing of a pattern is set. Access the SCALE SETUP menu by
pressing [FUNCTION] + [PATTERN PAGE]. This menu will look different depending on
whether NORMAL or PER TRACK is active. These settings are made in the PATTERN
SETTINGS menu. Read more on page 89. Use the [LEFT] and [RIGHT] arrow keys to
select between the available settings. The [UP] and [DOWN] arrow keys or the LEVEL
knob adjust the settings.

NORMAL

This is the default mode. In this mode all tracks of the pattern have the same length and
time signature. This screen will appear when the NORMAL setting, found in the PATTERN
SETTINGS menu, is active for all tracks.

PATTERN SCALE sets the number of steps in a pattern and thus the total amount of pat-
tern pages. The leftmost number selects the number of steps in the pattern. The maximum
number of steps available to the pattern is determined by the total length, set by the right-
most parameter. This can be either 16, 32, 48 or 64 steps. If 17 steps or more are used in a