AMP MAIN

Access the AMP MAIN page by pressing [AMP]. Here settings affecting the amplitude and
the stereo positioning of the track are found.

ATK sets the time it will take for the amplitude envelope to reach its full level.

HOLD sets the hold time of the amplitude envelope. The signal will be held at full level dur-
ing the duration of the hold phase. The hold phase is by default dependent on the BPM.
The parameter is expressed in the amount of sequencer steps the hold phase will last.

REL sets the time it will take for the signal to fade out once the hold phase is over.

VOL sets the volume of the track, pre effects. This setting affects signals being sent to both
the main and cue outputs.

BAL positions the sample in the stereo field.

XVOL is a setting that only will appear when pressing a [SCENE] key. This parameter can
only be locked to scenes. See “SCENES” on page 61 for more information.

AMP SETUP

Open the AMP SETUP menu by either pressing [FUNCTION] + [AMP] or quickly double
pressing [AMP]. The graphical envelope shows which parameters control which aspect of
the envelope. It is a static image and doesn’t reflect the current envelope settings.

AMP controls the behavior of the amplitude envelope.