Environmental requirements, Pending approvals – Hardy HI 1756-nDF User Manual

Page 10

Advertising
background image


6

Chapter 2

HI 1756 1DF

1 Weigh Scale Channel

HI 1756 2DF

2 Weigh Scale Channels

Update Rate

95(10.5ms) or 145(6.9ms) Updates per Second

Averages

1-255 User-selectable in Single Increments

WAVERSAVER®

User Selectable

OFF
7.50 Hz
3.50 Hz
1.00 Hz (Default)
0.50 Hz
0.25 Hz

Digital Voltmeter (Integrated Technician – Diagnostic Mode Only)

Accuracy ± 2% of full scale

Relay

Two integrated solid state DC or AC relays per weigh scale channel
Default state of relays will be OPEN (Form A - NO).
For resistive loads only. Cannot mix AC and DC relays on same module.
DC Relay
Capable of switching 5 to 30 VDC
Maximum current rating 3A @ 25

o

C, 2A @ 40

o

C, and 1A @ 60

o

C

Minimum load current 2mA
AC Relay
Capable of switching 24-280 (47-63Hz) VAC
Maximum current rating 0.5A @ 60

o

C

Minimum load current 70mA

Environmental Requirements

Operating Temperature Range

0 to 60º C (32º F to 140º F)

Temperature Coefficient

Less than 0.005% of full scale per degree C for Cal-LO and Cal-HI reference points

Storage Temperature Range

-40 to 85º C (-40 to 185º F)

Humidity Range

0-90% (non-condensing)

Pending Approvals

UL, CUL, and CE


Advertising