Chapter 4

Parameter
Name

Parameter
Number

Parameter
Default

Description

Waversaver

4.0

3

Waversaver Options

Ref#

Frequency (Hz)

0

OFF

1

7.50

2

3.50

3

1.00

4

0.50

5

0.25

Zero Track
enable

5.0

0

Enables the auto zero tolerance function
when 1.

Weight Filter

6.0

2

Weight filter selections

See Overview of Weight Calculation for
selection details.

Ref#

Filter

0

Raw ADC data samples

1

Filtered data samples

2

Waversaver output data

Refill mode

7.0

0

Setting to 1 the automatic refill mode is
enabled and the unit automatically starts a
refill cycle if the next dispense cycle will
lower the weight below the programmed
start refill weight value. The automatic
refill cycle is stopped when the weight
reaches the programmed stop refill weight
value. This is only available in single relay
mode.
When set to 0 the manual refill mode is
enabled and a STARTREFILL command is
required to start the refill cycle.

Weight Update
Rate

8.0

0

Sets the rate at which weight readings are
taken. Set to 0 for 145Hz mode and to 1 for
95Hz mode.

Material

9.0

0

To compensate for material flow rate, set
to 0 for liquids or fine materials and 1 for
coarse or “lumpy” materials.

Flow Rate
filter

10.0

1

Flow rate filter.

See Overview of Flow Rate Calculation
for selection details.

Ref#

Filter

0

Raw ADC data samples

1

Adaptive running avg

2

Short term running avg

3

Long term running avg